事件查看器磁盘错误 ID 7 51 55 129 和 153 表示硬件故障

早在硬盘完全失效之前,Windows 就会将证据以纯文本形式写入事件查看器系统日志,并带有准确的错误 ID。大多数用户从不看。以下是区分失效驱动器和 Windows 故障的五个 ID。

✍️ Technical Anshu🪟 Windows 10 / 11⏱️ 10 minute log check
Video Tutorial Thumbnail
🎥 观看视频,了解在真正出现故障的 PC 上发现的这些错误

当 PC 随机死机或 Windows 不断损坏时,猜测对任何人都没有帮助。 Windows 一直记录驱动器未能完成的每次读写操作。该日记就是事件查看器中的系统日志,里面每天都会引用维修店的五个事件ID:7、51、55、129和153。以下是每个人的确切措辞、其真正含义、严重程度以及正确的下一步 - 包括驱动器被证明是无辜的诚实案例。

Event Viewer — System log filtered to disk and Ntfs (example)
Error disk 7 The device, \Device\Harddisk0\DR0, has a bad block. Warning disk 51 An error was detected on device \Device\Harddisk0\DR0 during a paging operation. Warning disk 153 The IO operation at logical block address 0x475ea7a0 for Disk 0 was retried. Warning disk 129 Reset to device, \Device\RaidPort0, was issued. Error Ntfs 55 A corruption was discovered in the file system structure on volume C:.
Pattern to fear: the same IDs, every day, growing in numberAct now

👆 Windows 编写的五个硬件可疑事件的确切措辞 — 示例条目,已显示,以便您可以在自己的日志中识别它们。

1

如何在两分钟内找到这些事件

  1. 按 Windows + R,输入 eventvwr.msc,按 Enter
  2. 打开Windows日志→系统
  3. 单击右侧的过滤当前日志。在事件源中,勾选磁盘和Ntfs。在 ID 框中输入 7,11,51,55,98,129,153
  4. 按日期排序并查找重复。三个月前的一篇文章已经成为历史。本周十个条目是一个诊断
  5. 请注意每条消息所命名的磁盘。 Harddisk0 通常是 Windows 启动的驱动器 — 在“磁盘管理”中确认,它显示为“磁盘 0”
2

事件 ID 7 和 51 — 驱动器无法读取其自己的表面

  1. ID 7 —“设备 \Device\Harddisk0\DR0,有一个坏块。” 此列表中最强的单个条目。驱动器报告了一个无法读取的块——物理表面故障,以简单的文字记录。重复 ID 7 = 立即备份并计划更换
  2. ID 51 —“在分页操作期间...在设备上检测到错误。” 警告页面文件的 I/O 操作遇到错误。强制关机或电缆松动后,偶尔会出现 ID 51;每日 ID 51 与 ID 7 或 153 一起表示驱动器(或其连接)出现故障
  3. 相关:ID 11 —“驱动程序检测到控制器错误” 指向控制器、电缆或端口而不是磁盘表面,值得首先进行电缆交换测试
3

事件 ID 129 和 153 — 驱动器及时停止应答

  1. ID 153 —“磁盘 0 的逻辑块地址处的 IO 操作已重试。” 读取或写入花费了很长时间,以至于 Windows 放弃并重试。这是 10-60 秒冻结背后的条目,PC 随后会醒来,就像什么都没发生一样
  2. ID 129 —“重置设备...已发出。” 超时更进一步:Windows 重置整个存储设备以获得答案。重复 129 意味着驱动器挂在重试无法修复的级别
  3. 诚实的问题:坏的 SATA 电缆、故障端口、过时的存储驱动程序或激进的电源设置都可以产生相同的 129/153 条目。这就是为什么下一步是廉价的消除测试 - 新电缆、不同的端口、更新的存储驱动程序 - 在谴责驱动器之前
  4. If 129/153 continue on a known-good cable and port, and SMART shows pending or reallocated sectors, the drive is guilty beyond reasonable doubt
4

事件 ID 55 — Ntfs 发现损坏(和 ID 98)

  1. ID 55 (Ntfs) — "A corruption was discovered in the file system structure on volume C:." The file system's own bookkeeping is damaged. Microsoft 对 55(及其亲戚 50、98、140)的指导是运行 chkdsk - 但只有在您知道硬件运行状况良好之后
  2. ID 98 says a volume needs an offline chkdsk.同样的规则适用
  3. 原因是:文件系统损坏只有几个原因 - 突然断电、Windows 在写入过程中崩溃或驱动器无法可靠地存储数据。如果 ID 55单独出现,并且 SMART 干净并且没有磁盘源错误,则怀疑电源/崩溃历史记录并修复文件系统。如果 ID 55 与 7、51 或 153 并存,那么文件系统就是受害者,而不是罪魁祸首——在不更换驱动器的情况下修复它就像重新粉刷一堵墙,后面有一个泄漏的管道
5

将日志转化为决策

  1. IDs 7, 51, 129, 153 repeating + SMART Caution/Bad: hardware.首先拯救数据,更换驱动器,在新驱动器上重新安装 Windows
  2. 129/153 only, SMART fully clean: cable, port, driver or power settings. Swap the cable and port, update the storage driver, re-check for a few days
  3. ID 55/98 only, everything else clean: file system damage from crashes or power loss. Back up, then run chkdsk C: /scan and follow its verdict
  4. Nothing at all in the log: your problem is almost certainly not the drive. Move on to RAM, temperatures, drivers and Windows itself

看到这些实时识别的条目以及 SMART 检查,正是上面的视频所介绍的内容。

🔴不要清除系统日志来“清除”这些错误。您将删除最好的证据 - 如果电脑在保修期内,这些日期条目可以让服务中心相信驱动器确实出现了故障。

🎥 观看视频中的完整过程

在完整的诊断视频中,观看如何在真机上查找和判断这些确切的事件 ID,以及 SMART 运行状况检查。

▶️ Watch Full Video
❓ 常见问题

I found one Event ID 7 from two months ago and nothing since.我的驱动器快要死了吗?

单个隔离 ID 7 通常记录驱动器已通过重新分配处理的一个坏块。检查 CrystalDiskInfo:如果重新分配的扇区较低且稳定,待处理扇区为零,并且在接下来的几周内没有出现新的磁盘错误,则驱动器已吸收了损坏。照常备份并每月重新检查 - 计数不断增加会使疤痕变成死刑。

Why do IDs 129 and 153 appear on my SSD when it is only a few months old?

在新的 SSD 上,超时通常是由驱动器周围的连接和软件而不是磨损的闪存引起的:边缘 SATA 电缆、过时的存储控制器驱动程序、旧的 SSD 固件或激进的链路电源管理。更新固件和存储驱动程序,更改电缆和端口,并且仅在事件持续存在的情况下才怀疑 SSD 本身 - SMART 磨损和错误计数器通常会确认真正有故障的单元。

Windows keeps asking to scan and repair the drive at boot.同样的事情吗?

该提示来自卷上的脏位,通常与 ID 55 或 98 等 Ntfs 事件配对。让扫描运行并注意它是否不断返回。每隔几天返回一次扫描请求,其日志还显示磁盘源错误 7、51 或 153 的驱动器,这是由故障硬件引起的文件系统损坏的经典模式。

本指南基于技术安数硬盘诊断视频 • 卡在任何步骤上?在视频评论中提问 — 你会在那里得到回复🙏