Here is what admins have been reporting since the September 2026 security updates: Always On VPN profiles that worked for months suddenly hang at Connecting at sign-in, and manual retries fail with "The specified port is already in use" - even after a reboot, even though no VPN session exists. The story behind it is unusually honest for a bug: Microsoft first marked the issue resolved with the 13 October updates, then on 20 October withdrew that claim, apologised, and set the status back to "Mitigated" (advisory WI1482218). The root of it is the profile's automatic protocol selection: when the first protocol attempt fails, Windows no longer switches cleanly to the fallback, so the tunnel sticks half-open and keeps the port busy. The workaround removes that switching step entirely.
✖ Status never changes from Connecting - at sign-in and on every retry
✖ Manual connect attempt: "The specified port is already in use"
✔ Internet itself works fine - only the VPN tunnel is stuck
✔ Problem started after the September-October 2026 updates
✔ Profile's tunnel type is set to Automatic (IKEv2 / SSTP fallback)
The problem exactly as it appears: an Always On profile pinned forever at Connecting, with the port reported busy.
Before changing anything, confirm the profile is using automatic protocol selection - that is the trigger condition for this bug:
Get-VpnConnection | Select-Object Name, TunnelType
Get-VpnConnection -AllUserConnection | Select-Object Name, TunnelType
This is the workaround Microsoft documents for this issue: the profile must use one protocol, so there is no fallback step left to break. First decide which protocol your VPN server supports - IKEv2 is the usual Always On choice; SSTP is the fallback that rides on TCP 443 and survives restrictive networks. If you are a staff user, ask IT which one the gateway expects before changing it.
Route A - PowerShell (fastest, and the only route for device tunnels):
Set-VpnConnection -Name "CorpVPN" -TunnelType Ikev2
Set-VpnConnection -Name "CorpVPN" -TunnelType Sstp
Set-VpnConnection -AllUserConnection -Name "DeviceTunnel" -TunnelType Ikev2
Route B - Settings, for a normal user profile:
Admins deploying Always On VPN through Intune or a profile XML should make the same change at the source: set the profile's NativeProtocolType to IKEv2 or SSTP instead of Automatic, and redeploy - otherwise the next profile refresh will quietly undo the local fix.
Microsoft now points to the 28 October 2026 preview update KB5127936 as the resolution for this issue, and the same fix will flow into the regular cumulative updates after it. The practical advice for a fleet is deliberately boring:
Given that the "resolved" claim was already made once and retracted on 20 October, treating the pin as the working configuration - and the update as the thing to verify - is the honest order of operations.
Every week: Windows problems, hidden tools and full setup guides, explained step by step.
▶ Subscribe on YouTubeBecause the first connection attempt did not fully let go. After the September 2026 updates, when a VPN profile set to automatic protocol tries one protocol (say IKEv2) and that attempt fails, Windows fails to switch cleanly to the fallback (SSTP). The half-open attempt keeps the RAS port occupied, so the next attempt is told the specified port is already in use - even though no working VPN session exists. Pinning the profile to a single protocol removes the broken switching step entirely.
Whichever one your VPN server actually supports - ask your IT team if you do not know. IKEv2 is the modern default for Always On VPN device and user tunnels and is the better first choice where the gateway supports it. SSTP runs over TCP 443, so it often works from networks that block other VPN traffic, like hotel and guest WiFi. What matters is that the profile names exactly one protocol instead of Automatic.
Because the first resolution claim did not hold. Microsoft marked the Always On VPN issue resolved with the 13 October 2026 updates, then on 20 October it withdrew that claim, apologised, and set the status back to Mitigated - meaning a documented workaround exists but the underlying fault is not fully fixed. That is why the single-protocol pin in this guide is still the tested route, and why Microsoft now points to the 28 October preview update KB5127936 as the resolution while admins keep the workaround in place.
Do not do it - Microsoft explicitly advises against uninstalling the October security update for this problem. You would trade a broken VPN for an unpatched PC, and Always On VPN in an office exists to protect exactly that PC. Pin the profile to a single protocol instead; it restores the connection while the security update stays installed.
The known issue is documented around Always On VPN and profiles that use automatic protocol selection and fallback. A manually created VPN profile can show the same behaviour if it is also set to Automatic tunnel type. The check is identical either way: if TunnelType says Automatic, the profile is a candidate for this problem, and pinning it to IKEv2-only or SSTP-only is the documented workaround.