Long Cheap LAN Cables CCA Wire and the 100 Metre Gigabit Limit

The most expensive-looking cheap cable in the building is the one that passes every casual test and fails every real one. Cable quality faults are distance faults: perfect on a 2 metre bench test, guilty at 60 metres in the wall - which is why they survive years of troubleshooting.

Technical AnshuCCA CableCable Length
Watch the full case on video - a gigabit office link dropping bursts of ping, and the order the team worked the suspects in

Ethernet distances are electrical budgets. Gigabit signalling over twisted pair is specified for a 100 metre channel - roughly 90 metres of solid-core installed cable plus patch leads - using proper copper conductors of the right category. Every shortcut spends that budget faster: aluminium-core cable spends it on resistance, flat cable spends it on crosstalk, and sloppy terminations spend it at both ends. A link can be inside the length limit and still be outside the electrical one.

Same Run, Two Test Points (Example)
PC at switch, 2 m patch lead1 Gbps, clean
PC at desk, full wall run100 Mbps, drops
VerdictThe run or its ends

Example only: if the same PC is perfect at the switch and faulty at the desk, the PC is innocent and the installed run - cable, jacks, patch panel - owns the fault.

1

CCA - The Cheap Cable That Is Not Copper

Much budget cable is CCA: copper-clad aluminium. An aluminium core with a copper skin conducts worse than solid copper - higher resistance on every metre - and it is brittle, work-hardens at bends, and oxidises at terminations. At 3 metres you will never know. At 60 metres it can be the difference between gigabit and fallback, and under PoE it heats more and drops more voltage than copper, which is why cameras on CCA runs reboot on cold nights. It is also sold with honest-looking category labels. Price and weight give it away; a magnet will not, but experienced buyers cut and look at the silver core.

2

Flat Cables, Kinks and Hostile Routes

Flat under-carpet cables trade the twisted-pair geometry that cancels interference for convenience - fine for a short run in a quiet room, marginal beside power cables. Tight kinks and crushed sections change a pair's spacing permanently; a chair leg can create a fault that appears only when someone sits down. And routes matter: a run strapped alongside lift motor feeds, big UPS outputs or fluorescent ballasts drinks interference for its whole life. If drops correlate with the lift or the AC compressor starting, stop testing software and go look at the route.

3

The Honest Category Talk

Cat5e, honestly installed, carries gigabit to the full 100 metres - that is the specification, not optimism. Cat6 buys margin and future speed, not magic, and no category rescues a bad termination. Conversely, ancient genuine Cat5 or a run re-purposed from telephone wiring may negotiate 100 Mbps happily and never hold gigabit. Judge the installed result - link speed, error counters, length - instead of the printing on the jacket, which describes the day the cable was made, not the decade since.

4

Testing a Long Run Without Guessing

  1. Bypass: connect the PC at the switch with a short known-good lead. Clean result moves guilt into the run
  2. Swap the desk patch lead and re-punch both ends of the run - terminations before cable, always
  3. Read link speed and port error counters during a big copy; marginal runs fail under real gigabit traffic, not at idle
  4. Measure the actual run length honestly - ceiling detours surprise everyone; a 100 metre run is often 130 by the time it dodges pillars
  5. If the run is over length or CCA and loaded, the durable fix is a mid-point switch or a re-run in solid copper - not a booster, not hope
Honest note: expensive cable does not fix cheap workmanship, and a famous brand printed on the jacket proves nothing about the decade in the ceiling. Diagnose the installed channel - speed, errors, length, terminations - and let the numbers decide whether the run can be rescued at its ends or has to be replaced.

Watch the Full Ping Drop Troubleshooting Video

See the video case - a reminder that the cable is one suspect among several, and it was cleared by test before the real culprit was found.

Watch Full Video
Frequently Asked Questions

Is CCA cable really that bad?

For a short desktop lead, you may never notice it. The problems grow with length and load: aluminium has higher resistance, so long CCA runs lose signal margin, run hotter under PoE and age badly at terminations. For installed runs and gigabit at distance, solid copper is the specification, not a luxury.

Can Cat5e really do gigabit at 100 metres?

Yes - gigabit Ethernet was designed for exactly that: 1000 Mbps over a 100 metre channel of Cat5e or better, properly terminated. Most real-world failures at length are termination quality, CCA conductors, detours that push the true length past the limit, or interference on the route - not the category itself.

My link is fine at 100 Mbps but drops at gigabit over a long run. Why?

Gigabit stresses the channel far harder: all four pairs, both directions, tighter signal margins. A run with barely enough margin passes at 100 and fails at gigabit, especially under full-speed traffic. Shorten the path with a mid-point switch or replace the run - marginal physics will not heal.

This guide is based on the Technical Anshu ping drop and Speed and Duplex video • Stuck on any step? Ask in the video comments - you will get a reply there